Re-Calibration
You should consider re-calibrate the battery if you are not sure about the battery health.
Here is the step to perform battery re-calibration for Unraid server:
- Stop Unraid APC UPS Daemon.
- RUN
apctest
from command-line.
- Select Option 2) Perform self-test.
- Once done, select Option 10) Perform battery calibration.
- Start Unraid APC UPS Daemon again.
- You should see the new runtime estimation on Unraid server.
Battery Replacement
If the Re-Calibration does not help increase the runtime estimation, then it is time to actually replace the battery.
Here is the step to replace the battery:
- Shutdown the system.
- Unplug everything from the UPS.
- Replace the battery.
- Power on the system.
- Once the system is online, stop Unraid APC Daemon.
- RUN
apctest
from command-line.
- Select Option 2) Perform self-test.
- Once done, select Option 4) View/Change battery date.
At this step, you should update the battery change date.